FLUKE 190-062-III Oscilloscope เครื่องมือทดสอบ ScopeMeter Test Tools
FLUKE-190-062-III
FLUKE 190-062-III Oscilloscope เครื่องมือทดสอบ ScopeMeter Test Tools SB and Wi-Fi download for analyzing data with FlukeView® software CAT III 1000 V/CAT IV 600 V
Index
FLUKE-190-062-III ฟังก์ชั่นการวัด
Oscilloscope เครื่องมือทดสอบ ScopeMeter Test Tools
FLUKE-190-062-III จุดเด่น
Rated for industrial environments CAT III 1000 V/CAT IV 600 V
Automatically capture, view and analyze complex waveforms
Large, bright color display for easy in-the-field viewing
USB and Wi-Fi download for analyzing data with FlukeView® software
Up to four independent floating isolated inputs, up to 1000 V
FLUKE-190-062-III ช่วงการวัด
Voltage
V dc accuracy ± (0.5 % + 6 counts) ± (1.5 % + 6 counts)
V ac true rms accuracy
15 Hz to 60 Hz ± (1 % + 10 counts) ± (1.5 % + 10 counts)
60 Hz to 1 kHz ± (2.5 % + 15 counts) —
60 Hz to 20 kHz — ± (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz ± (1 % + 10 counts) ± (1.5 % + 10 counts)
60 Hz to 1 kHz ± (2.5% + 15 counts) —
60 Hz to 20 kHz — ± (2.5 % + 15 counts)
Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,100 V
Resistance
Ranges 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy ± (0.6 % + 6 counts)
Other meter functions
Continuity Beeper on < 50 Ω (± 30 Ω)
Diode test Up to 2.8 V
Current (A) A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
Temperature With optional accessories. Scale factors 1mV/°C or 1mV/°F
FLUKE-190-062-III Power Supply
Re-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery]
BP290: 10.8V, 2500 mAh
[BP291 (5000 mAh) optional]
FLUKE-190-062-III ขนาดสินค้า
Display size 133 mm x 90 mm (5.3 in x 3.5 in) LCD
265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in)
Weight (including battery) 2.1 kg (4.6 lb)
FLUKE-190-062-III อุปกรณ์ที่มาในชุด
Battery charger/ mains adapter
Li-Ion battery pack
2 pcs VPS421-x, ruggedized industrial-grade probes, 100:1, 150MHz with shrouded 4mm banana tip and large jaw alligator clips (one red, one blue)
FLUKE-190-062-III ข้อมูลจำเพาะ
Vertical deflection
Number of channels 2
Bandwidth 60 MHz
Rise time 5.8 ns
Number of scope inputs 2 input channels plus external trigger
Channel architecture All inputs fully insulated from each other and from ground. Inputs may be activated in any combination.
Input coupling AC or DC, with ground level indicator
Input sensitivity
With 10:1 probe, 20 mV to 1000 V/div
With 100:1 probe, 200 mV to 10 kV/div
Direct (1:1), 2 mV to 100 V/div
Bandwidth limiter 20 MHz and 10 kHz
Polarity Normal, Inverted, Variable
Input voltage CAT III 1000 V/CAT IV 600 V rated, see General specifications for further details
Vertical resolution 8 bit
Accuracy at 4 s to 10 μs/div
5 mV/div to 100 V/div, ±(1.5 % + 6 counts)
2 mV/div, ±(1.5 % + 10 counts)
Input impedance 1 MΩ (± 1 %) // 15 pF (± 2.25 pF)
Horizontal
Maximum real- time sample rate (sampled simultaneously) 625 MS/s (each channel)
Record length Up to 10,000 samples per channel
Time base range
10 ns/div to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length
10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy ± (0.01 % of reading + 1 pixel)
Glitch capture 8 ns (10 µs/div to 2 min/div)
Display and acquisition
Display 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD
Display modes Any combination of channels; average on/off; replay.
Visible screen width 12 divisions horizontally in scope mode
Digital persistence modes Off, short, medium, long, infinite and envelope mode
Waveform mathematics
One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT
Acquisition modes
Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
Source Input A, B or External (via meter input)
Modes Automatic, Edge, Pulse Width, N-Cycle, External (190-xx2)
Connect-and- View™
Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Pulse width triggering (on channel A)
Pulse width qualified by time
Allows for triggeringt, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggering Triggers on both rising and falling edges alike
N-cycle triggering Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events.
Replay
Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storage
Ten sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window Automatic, Hamming, Hanning or None
Automatic window Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant.
Vertical scale Linear/Logarithmic (in volts or amps)
Frequency axis Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform compare
Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope.
Pass/Fail testing
In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio;
Advanced power and motor drive functions
V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters
Cursor measurements
Source On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors.
Single vertical line Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
Advanced functions mA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors)
ZOOM Ranges from full record overview to zoom in up to sample level, at any record length.
Meter inputs Via 4 mm banana inputs, fully isolated from scope inputs and scope ground
Number of readings One at a time via DMM input
Maximum resolution 5,000 counts
Input impedance 1 MΩ (± 1 %) // 14 pF (± 1.5 pF)
Advanced meter functions
Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Input voltage range
Rated maximum floating voltage
CAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410-II
CAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead)
Probe input voltage VPS421
CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead)
Maximum BNC input voltage CAT IV 300 V (maximum voltage on BNC input directly)
Maximum volt- age on meter input CAT III 1000 V / CAT IV 600 V
(safety designed banana input connectors)