SPC output function offers quick and easy data management in real time
ABSOLUTE (ABS) linear scale eliminates the need for setting the origin point every time the micrometer is powered on; overspeed errors are also eliminated
Functions include Origin Set, Zero Setting, Power On/Off, Data Output and inch/mm conversion
Alarm: Low Voltage, Counting Value Composition Error
Constructed of hardened stainless steel for better durability and longevity
IP67 protection eliminates dust ingress, protects against temporary water submersion; permits use in environments exposed to cutting oil, dust, etc.
Unnecessary to wipe or clean the scale
Supplied in fitted plastic case
Specifications
Range
(20 to 150) mm , (0.8 to 6)”
Resolution
0.01 mm , 0.0005″
Accuracy
± 0.0020″
Mass
157 g
Remarks
Point jaw type
Display
LCD
Measurable Min. Hole Diameter
ø 0.8″
Length Standard
ABSOLUTE electrostatic induction type linear encoder